Huawei MA5608T MA5600T GPON EPON OLT
Original HUAWEI FTTH Optical Line Terminal Smartax Ma5608T Mini EPON GPON OLT
Production Description:
- Aggregate Access:
- Ultra-high convergence switching capacity, 3.2T backplane capacity, 1920G switching capacity, 512G MAC address capacity;
- Ultra-high-density cascade capability, maximum support for 44-channel 10GE or 768 GE access, no additional investment aggregation switch.
- High Reliability:
- Highly reliable networking capabilities, support OLT dual hot backup, off-site capacity,upgrade business is not interrupted
- Complete QoS function, support traffic classification management, priority control, with paragraph control. H-QoS functions to meet SLA requirements for diverse business customers.
- End-to end high reliability design, uplink support BFD/Smart Link/LACP redundancy protection, support EPON TypeB / TypeD and GPON TypeB / TypeC line protection.
- Multi-scene access:
- A variety of E1 line access, support Native TDM or CESoP / SAToP function.
- Support E-LAN function to achieve internal traffic flow based on VLAN to meet the enterprise and campus network applications.
- Support IPTV users without convergence access, single-frame support 8000 multicast users and 4000 multicast channels.
- Smooth Evolution:
- EPON / GPON / 10G PON / 40G PON common platform to support smooth evolution, to meet the ultra-wideband access.
- Support IPv4 / IPv6 dual stack, support IPv6 multicast, to achieve the smooth evolution of IPv4 to IPv6.
- Green Technology:
- Unique chip technology, high-density 16 port GPON board power consumption does not exceed 73W.
- Support free board automatic power, fan intelligent speed, effectively reduce the idle power consumption.
Specifications and Characteristics of the List:
|
Model No.
|
MA5680T
|
MA5683T
|
MA5608T
|
|
Dimension:
|
490*275.8*447.2mm
|
442*283.2*263mm
|
442*233.5*88mm
|
|
Operating Environment
|
Temperature: -25℃~+55℃ Humidity:5%~95% (non-condensing)
|
Temperature: -40℃~+65℃ Humidity:5%~95% (non-condensing)
|
Temperature: -40℃~+65℃ Humidity:5%~95% (non-condensing)
|
|
Power Supply Parameters
|
-48V DC input Supports dual power protection Working Voltage range -38.4V~-72V
|
-48V DC input Supports dual power protection Working Voltage range -38.4V~-72V
|
-48V DC input Supports dual power protection Working Voltage range -38.4V~-72V Support 220V / 110V AC input
|
|
Backplane Exchange capacity
|
3.2Tbit/s
|
1.5Tbit/s
|
720Gbit/s
|
|
Control Board Exchange Capacity
|
1920 Gbit/s
|
960Gbit/s
|
512Gbit/s
|
|
Access Capacity
|
128*10G EPON 64*10G GPON 128*EPON 256*GPON 768*GE
|
48*10G EPON 24*10G GPON 48*EPON 96*GPON 288*GE
|
16*10G EPON 8*10G GPON 16*EPON 32*GPON 96*GE
|
|
Access Type
|
Upstream interface: 10GE optical, GE optical/electricity Business interface: EPON optical port, GPON optical port, 10G EPON optical port, P2P FE optical port, P2P GE optical port, Ethernet optical interface
|
|
System Performance
|
Layer 2 / Layer 3 wire-speed forwarding Support static router /RIP/OSPE.MPLS BITS/E1/STM-1/Ethernet/1588v2/1PPS+ToD clock Maximum support 1:256 splitting ratio Maximum support 60KM logical distance
|
Products Hardware Details Pictures & Description:
- Small size control unit board contrast:
The small size of the super control unit board (MCUmain control board) support the following functions:
- System control management unit..
- Active / standby switchover and load sharing.
- Maintain serial port CON and maintain network port ETH, support local and remote maintenance.
- Environmental monitoring access.
- Ethernet synchronization.
- Temperature reading and high temperature alarm.
- Fan frame monitoring and management.
- 7 Road alarm switch input, 1 alarm switch control output.
- Optical and Copper mixed access.
-
- 1G Control & Uplink Board (MCUD):
H801 MCUN the functions of each module are as follow:
- Control module to achieve the management of the board and the business board.
- Logic module to achieve logic control.
- The power supply module provides working power for each function module in the board.
- The clock module provides the working clock for each function module in the board.
- The switch module provides GE/10GE interface to implement service switching and aggregation based on layer 2 or layer 3.
--Provides 4 GE for upstream uplink interface.
--2 GE/10GE are provided for GE/10GE exchange with each service board.
--Provide 1 10GE, and standby H801MCUN to achieve load sharing.
- 10G Control & Uplink Board (MCUD1):
H801 MCUN1 the functions of each module are as follows:
- Control module to achieve the management of the board and the business board.
- Logic module to achieve logic control and three clock functions.
- The power supply module provides working power for each function module in the board.
- The clock module provides the working clock for each function module in the board.
- The switch module provides GE/10GE interface to implement service switching and aggregation based on layer 2 or layer 3.
--2 GE /10GE and 2 GE are provided for upstream uplink interface.
--2 GE/10GE are provided for GE/10GE exchange with each service board.
The function of each module of the H801MPWC board is as follows:
- H801MPWC board by a 3V3 power connector to introduce a road -48V power supply, through the filter circuit and current limiting protection circuit output to the backplane for the chassis other power supply.
- Check the reported circuit to the protection of the fuse for fault detection, the detected signal and the board in-position signal together reported to the main control board, and through the light display.
- Detection report circuit detection input undervoltage and input power supply.
- E2PROM circuit is user storage board manufacturing information.
- Introduce the 5V / 3.3V power supply from the backplane to power the internal chip in the board.
The function of each module of the H801MPWD board is as follows:
- AC input, AC/DC changes, the output -48V (voltage adjustable ) to the system backplane.
- Support battery access, battery charge and discharge management by the monitoring board to achieve.
- Through the backplane to communicate with system, reported board hardware information, electronic tag information.
- Power board and monitoring board through the 485 protocol communication, to achieve voltage regulation, regulation and reporting of alarm information function.
- Monitoring board to support lead-acid battery management.
- Optocoupler control battery power down.
- Provide power distribution detection and reporting alarm function.